Inspection · Inspected 2026-08-01 · Inspector: A. Sample
SAMPLE REPORT — a fictional house, shown so you can see exactly what your clients receive. Every element works, including the repair-request builder below.
Your Inspection Report
Every finding below was observed and committed by your licensed inspector — A. Sample, HI0000. Plain English throughout; the certified PDF is the formal record.
ST-01MinorRoof framing — attic, over the garageFull detail →
A section of roof truss over the garage has been field-modified: one diagonal web member was cut and is no longer connected at its lower chord, apparently to route the garage door opener's power conduit. The cut end shows no sistering, gusset, or engineered repair. Two adjacent trusses show the original members intact and undisturbed, so this appears isolated to the single truss rather than a pattern repeated across the garage bay.
Why it matters: Roof trusses are engineered as complete triangulated systems; every web member is load-bearing by design, not incidental bracing. Removing one diagonal shifts load paths the rest of the truss and its neighbors were never sized to carry, and that redistribution isn't visible until it shows up as sag, cracked drywall, or a sheathing failure under wind or added roof load — by which point the fix is far more invasive than it would be today.
Have a qualified specialist evaluate it. by a licensed structural engineer, before any additional roof load (a second layer of shingles, added HVAC equipment, solar) is placed on this section
Reference detail — how a correct installation looks. An illustration for explanation, not a photograph of this home.
Ground surface slopes toward the structure at the northeast corner.
Why it matters: Rainwater is directed at the foundation instead of away from it — the most common source of under-slab moisture problems.
Have it corrected.
Water follows the slope. Comparison of ground sloping toward a foundation and ground sloping away. The drawing shows surface runoff, not subsurface drainage.
Asphalt shingle covering shows widespread granule loss and cupping; approximately 19 years old per the county permit record.
Why it matters: Florida sun and rain wear a shingle roof from the day it's installed; at this age and condition it is at the end of its expected service life.
Have a qualified specialist evaluate it.
This component is at or near the end of its expected service life.
Two signs of shingle wear. A surface close-up illustrates granule loss; a side profile illustrates cupping. These are independent examples, not an image or diagnosis of the subject roof.
Why it matters: These panels have a documented history of breakers failing to trip under fault — the one job a breaker has. Many insurers decline them outright.
Have a qualified specialist evaluate it.
Reference detail — how a correct installation looks. An illustration for explanation, not a photograph of this home.
Two conductors landed under a single breaker lug at position 12.
Why it matters: Lugs are rated for one wire unless marked otherwise; a loose second conductor can arc and overheat inside the panel.
Have it corrected.
From the panel to one connection. A schematic overview and enlarged terminal show two conductors entering one connection. Suitability depends on the actual terminal rating; this is not a photograph of the inspected panel.
Reference illustration — not this property.
Match the connection to its rating. Left: one conductor. Right: two at a common terminal. Multiple conductors are suitable only where the terminal is identified for that arrangement; this is not a wiring instruction.
Reference illustration — not this property.
HVAC
HV-01MinorCondensate line — air handler closetFull detail →
Condensate line shows a slow drip at the air handler pan connection; the secondary pan is dry.
Why it matters: A slow drip left unaddressed eventually overflows the primary pan and stains the ceiling below — this one is still ahead of that point.
Keep an eye on it.
Reference detail — how a correct installation looks. An illustration for explanation, not a photograph of this home.
Why it matters: The temperature-pressure relief valve is the tank's last safety device; without a discharge pipe, a release scalds whoever is standing there.
Have it corrected.
Give relief water a safe route. Example of an unobstructed discharge pipe from a temperature-and-pressure relief valve. The illustrated endpoint is conceptual; approved routing, material and termination depend on the installation.
Reference illustration — not this property.
A missing pipe leaves the release unrouted. The relief valve is present but its discharge outlet has no pipe. An uncapped outlet can still release hot water; the missing pipe leaves that release uncontrolled. A capped or blocked outlet is a different condition.
Elevated moisture signature behind the master shower tile, confirmed by meter reading.
Why it matters: A thermal anomaly with a matching moisture-meter reading points at an active leak inside the wall — the kind of damage that grows quietly.
Water heater appears approximately 4 years old; no matching permit from that period appears in the county records this report can reach. The most recent plumbing permit on file is dated 1998-04-11.
Why it matters: Work of this kind normally requires a permit. Unpermitted work conveys to the buyer — verifying with the installing contractor or the building department is cheap before closing and expensive after.
Have a qualified specialist evaluate it.
✓ Cross-referenced against the county permit record (permit PL98-0411) by your inspector.