Start with what matters
EL-01
Safety
Panel — garage
These panels have a documented history of breakers failing to trip under fault — the one job a breaker has.
EL-02
Safety
Panel — garage
Lugs are rated for one wire unless marked otherwise; a loose second conductor can arc and overheat inside the panel.
PL-03
Safety
Water heater
The temperature-pressure relief valve is the tank's last safety device; without a discharge pipe, a release scalds whoever is standing there.
RF-01
Major
Covering
Florida sun and rain wear a shingle roof from the day it's installed; at this age and condition it is at the end of its expected service life.
PL-02
Major
Shower wall — master bath
A thermal anomaly with a matching moisture-meter reading points at an active leak inside the wall — the kind of damage that grows quietly.
Structure
Exterior
Roof Covering
RF-01
Major
Covering
Florida sun and rain wear a shingle roof from the day it's installed; at this age and condition it is at the end of its expected service life.
RF-02
Couldn't fully inspect
Roof Covering
Slope excessive to safely walk on.
Electrical
EL-01
Safety
Panel — garage
These panels have a documented history of breakers failing to trip under fault — the one job a breaker has.
EL-02
Safety
Panel — garage
Lugs are rated for one wire unless marked otherwise; a loose second conductor can arc and overheat inside the panel.
HVAC
Plumbing
PL-03
Safety
Water heater
The temperature-pressure relief valve is the tank's last safety device; without a discharge pipe, a release scalds whoever is standing there.
PL-02
Major
Shower wall — master bath
A thermal anomaly with a matching moisture-meter reading points at an active leak inside the wall — the kind of damage that grows quietly.
PL-01
Minor
water heater
Work of this kind normally requires a permit.
Interior
EL-02
Safety
Panel — garage
Observed
Two conductors landed under a single breaker lug at position 12.
Why it matters
Lugs are rated for one wire unless marked otherwise; a loose second conductor can arc and overheat inside the panel.
Reference
Educational illustrations, not photos of this property — each is labeled below.
From the panel to one connection. A schematic overview and enlarged terminal show two conductors entering one connection. Suitability depends on the actual terminal rating; this is not a photograph of the inspected panel.
Reference illustration — not this property.
Match the connection to its rating. Left: one conductor. Right: two at a common terminal. Multiple conductors are suitable only where the terminal is identified for that arrangement; this is not a wiring instruction.
Reference illustration — not this property.
Next step
Have it corrected.