SAMPLE REPORT — a fictional house, shown so you can see exactly what your clients receive.
← Back to overview
Start with what matters
EL-01
Safety
Panel — garage
These panels have a documented history of breakers failing to trip under fault — the one job a breaker has.
EL-02
Safety
Panel — garage
Lugs are rated for one wire unless marked otherwise; a loose second conductor can arc and overheat inside the panel.
PL-03
Safety
Water heater
The temperature-pressure relief valve is the tank's last safety device; without a discharge pipe, a release scalds whoever is standing there.
RF-01
Major
Covering
Florida sun and rain wear a shingle roof from the day it's installed; at this age and condition it is at the end of its expected service life.
PL-02
Major
Shower wall — master bath
A thermal anomaly with a matching moisture-meter reading points at an active leak inside the wall — the kind of damage that grows quietly.
Structure
Exterior
Roof Covering
RF-01
Major
Covering
Florida sun and rain wear a shingle roof from the day it's installed; at this age and condition it is at the end of its expected service life.
RF-02
Couldn't fully inspect
Roof Covering
Slope excessive to safely walk on.
Electrical
EL-01
Safety
Panel — garage
These panels have a documented history of breakers failing to trip under fault — the one job a breaker has.
EL-02
Safety
Panel — garage
Lugs are rated for one wire unless marked otherwise; a loose second conductor can arc and overheat inside the panel.
HVAC
Plumbing
PL-03
Safety
Water heater
The temperature-pressure relief valve is the tank's last safety device; without a discharge pipe, a release scalds whoever is standing there.
PL-02
Major
Shower wall — master bath
A thermal anomaly with a matching moisture-meter reading points at an active leak inside the wall — the kind of damage that grows quietly.
PL-01
Minor
water heater
Work of this kind normally requires a permit.
Interior
EX-01
Maintenance
Grading — NE corner
Observed
Ground surface slopes toward the structure at the northeast corner.
Why it matters
Rainwater is directed at the foundation instead of away from it — the most common source of under-slab moisture problems.
Reference
Educational illustrations, not photos of this property — each is labeled below.
Water follows the slope. Comparison of ground sloping toward a foundation and ground sloping away. The drawing shows surface runoff, not subsurface drainage.
Reference illustration — not this property.
Next step
Have it corrected.